Document Outline

R
Clogged Air Filter Sensor
D6A
Detect Clogged Fan Filters to Prevent
Overheating of Equipment
H
Sensor detects air flow over a 0.5 to
1.5 m/sec range; provides analog
voltage output of 0 to 5 VDC
H
Algorithms provide a temperature
reference point to determine if a filter
fan is moving the right amount of air
H
Wide operating temperature range: 0 to
45C
H
Low current consumption: 60 mA
H
Ideal for computer servers, routers and
network devices; uninterruptible power
supplies and cash registers
Ordering Information
Output range
Wind velocity
Operating voltage
Part number
0.2 to 5 VDC at 1.5 m/sec velocity
0.5 to 1.5 m/sec
12 VDC
D6A
Specifications
J
RATINGS
Method of detection
Wind velocity
Wind velocity range
0.5 to 1.5 m/sec
Fixed temperature reference
80C
Supply voltage
12 VDC 10%
Current consumption
60 mA or less
Leakage current
1 mA or less
Maximum output voltage
5.2 V or less
Output voltage
0.25 V 1.2 V at 0.5 m/sec velocity
2.70 V 1.35 V at 1.0 m/sec velocity
4.50 V 1.35 V at 1.5 m/sec velocity
Power supply voltage: 12 VDC
Load resistance: 1 M
Ambient temperature 25 5C
J
CHARACTERISTICS
Insulation resistance
20 M or more for insulation between the terminal and the sensor body with 100 VDC
insulation resistance meter.
Dielectric strength
Applies 500 VAC to the input of the terminal for one minute between output terminals
Operating temperature range
0 to 45C (do not freeze)
Storage temperature range
--25 to 65C
Relative humidity
25% to 85% RH
D6A
D6A
2
Dimensions
Unit: mm (inch)
Precautions
J
HANDLING
1. Do not apply a voltage of 13.2VDC or more.
2. The output voltage decreases when oil, moisture and dust
adhere to the thermally sensitive resistor. Wipe down the
resistor during maintenance.
3. The output voltage decreases when the terminal winds when
the thermally sensitivie resistor is cleaned.
4. An internal circuit can be short-circuited when water or dust
reaches the printed circuit board.
5. Avoid electrical shock. Do not touch the thermally sensitivie
resistor terminal with fingers or hands.
6. Avoid serious burns. Do not touch the thermally sensitive
resistor because it is heated to 80C.
7. Dispose of the sensor properly when it no longer operates.
Cat. No. E10DAD1
06/02
Specifications subject to change without notice.
Printed in U.S.A.
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
847-882-2288
OMRON CANADA, INC.
885 Milner Avenue
Toronto, Ontario M1B 5V8
416-286-6465
R
OMRON ON-LINE
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci