ChipFind - документация

Электронный компонент: M57147AU-01

Скачать:  PDF   ZIP
OUTLINE DRAWING
HYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT
BLOCK DIAGRAM
DESCRIPTION
The M57147AU-01 is an insulated DC-DC converter de-
signed to drive the IPM. 6 outputs can obtain from an input
of 140 ~ 380VDC.
The terminals between inputs and outputs, and each outputs
are insulated.
FEATURES
Input ................................................... 140 ~ 380VDC
Output ................................................ +15V, 50mAX3
+15V, 150mAX1
+12V, 400mAX1
+5V, 300mAX1
Electrical isolation (between input and outputs)
........................................................... 1500Vrms 1minute
Electrical isolation (between each outputs)
........................................................... 1500Vrms 1minute
APPLICATION
Power supply for IPM drive
Dimensions: mm
18
1
19
36
M57147AU-01
XXXX
Lot No
Pin No
82MAX
50
0.7
80.35
0.35 0.2
2.54
0.55 0.1
2.54 17=43
33 MAX
1.6
4.5
1.5
(3.41)
Control circuit
Vo1+
Vo2+
Vo3+
Vo4+
18
Vo6+
Vo5+
Vin+
Vin
17
16
12
11
10
Vo5,6
Vo4
Vo3
Vo2
Vo1
19
20
24
25
29
30
35
1
2
3
5
4
34
HYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT
MAXIMUM RATINGS
(Ta = 25 C, unless otherwise noted)
V
V
V
V
mA
C
C
W
Vrms
Vrms
380
50
150
400
300
10 ~ 70
20 ~ 85
*10.8
1500
1500
Ratings
Symbol Parameter Conditions Unit
140
14
14
14
14
11
4.75
15
15
15
15
12
5.0
0.3
0.3
0.3
0.3
0.2
0.1
380
16
16
16
16
14
5.25
0.5
0.5
0.5
0.5
0.5
0.2
Symbol
Unit
Parameter
Test Conditions
Limits
Min.
Typ.
Max.
Input voltage
Output current
Operating temperature
Storage temperature
Total output power
Electrical isolation between input and outputs
Electrical isolation between each outputs
Vin
I
L
T
opr
T
stg
Po
Viso1
Viso2
Vo1, Vo2, Vo3
Vo4
Vo5
Vo6
No condensation
No condensation
Sine wave voltage, 60Hz, 1 minutes
Sine wave voltage, 60Hz, 1 minutes
Recommended range
Io1 = 5 ~ 50mA, Io2 = Io3 = 5mA, Io4 = 25mA
Io5 = 200mA, Io6 = 200mA
Io2 = 5 ~ 50mA, Io1 = Io3 = 5mA, Io4 = 25mA
Io5 = 200mA, Io6 = 200mA
Io3 = 5 ~ 50mA, Io1 = Io2 = 5mA, Io4= 25mA
Io5 = 200mA, Io6 = 200mA
Io4 = 25 ~ 150mA, Io1 = Io2 = Io3 = 5mA
Io5 = 200mA, Io6 = 200mA
Io5 = 30 ~ 400mA, Io1 = Io2 = Io3 = 5mA, Io4 = 25mA
Io6 = 200mA
Io6 = 50 ~ 300mA, Io1 = Io2 = Io3 = 5mA, Io4 = 25mA
Io5 = 200mA
Vo1 voltage change
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Io6 = 300mA
Vo2 voltage change
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Io6 = 300mA
Vo3 voltage change
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Io6 = 300mA
Vo4 voltage change
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Io6 = 300mA
Vo5 voltage change
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Io6 = 300mA
Vo6 voltage change
Io1 = Io2 = Io3 = 50mA, Io4 =150mA, Io5 = 400mA,
Io6 = 300mA
Vin
Vo1
Vo2
Vo3
Vo4
Vo5
Vo6
Reg-I
Input voltage
Output voltage
Line regulation
ELECTRICAL CHARACTERISTICS
(Vin= 140 ~ 380V, Ta = 25 C, Unless otherwise noted)
*Refer to Output Power vs.Input Voltage Charactreristics
HYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT
V
%
70
0.4
0.4
0.4
0.5
1.5
0.1
77
1.0
1.0
1.0
1.0
1.8
0.2
Symbol
Unit
Parameter
Test Conditions
Limits
Min.
Typ.
Max.
Vo1 voltage change
Io1 = 5 ~ 50mA, Io2 = Io3 = 50mA, Io4 = 150mA,
Io5 = 400mA, Io6 = 300mA, Vin = 300V
Vo2 voltage change
Io2 = 5 ~ 50mA, Io1 = Io3 = 50mA, Io4 = 150mA,
Io5 = 400mA, Io6 = 300mA, Vin = 300V
Vo3 voltage change
Io3 = 5 ~ 50mA, Io1 = Io2 = 50mA, Io4 = 150mA,
Io5 = 400mA, Io6 = 300mA, Vin = 300V
Vo4 voltage change
Io4 = 25 ~ 150mA, Io1 = Io2 = Io3 = 50mA,,
Io5 = 400mA, Io6 = 300mA, Vin = 300V
Vo5 voltage change
Io5 = 30 ~ 400mA, Io1 = Io2 = Io3 =50mA,
Io4 =150mA, Io6 = 300mA, Vin = 300V
Vo6 voltage change
Io6 = 50 ~ 300mA, Io1 = Io2 = Io3 = 50mA,
Io4 =150mA, Io5 = 400mA, Vin = 300V
Vin = 300V, Po = 10.8W
Reg-L
Load regulation
Efficiency
ELECTRICAL CHARACTERISTICS
(Vin= 140 ~ 380V, Ta = 25 C, unless otherwise noted)
TYPICAL CHARACTERISTICS
AVAILABLE IPM EXAMPLES
PM100CVA060
PM10CSJ060
PM100CSA060
PM50RSA060
PM50RSK060
PM15CTM060
PM150CVA060
PM15CSJ060
PM150CSA060
PM75RSA060
PM75RSK060
PM15CTM060-3
PM200CVA060
PM20CSJ060
PM200CSA060
PM100RSA060
PM20CTM060
PM30CSJ060
PM150RSA060
PM30CTJ060
PM20CTM060-3
PM50CTK060
PM30CTJ060-3
PM75RVA060
PM30RSF060
PM75CTK060
AC200~240V
+
V
IN
+
V
UP1
V
UPC
V
VP1
V
WP1
U
P
V
VPC
V
WPC
V
P
W
P
U
N
V
N
W
N
IPM
F
0
V
N1
EX.
PM15/20CT
M060(-3)
V
O
1+
V
O
1
V
O
2
V
O
2+
V
O
3+
V
O
5+
V
O
6+
V
O
5, V
V
O
4+
M57147AU-01
V
O
3
V
O
4
V
IN
LOAD
+
+
+
+
LOAD
HYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT
IHYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT
FOR SAFETY USING
Great detail and careful attention are given to the production activity of Hics, such as the development, the quality of production,
and in it's reliability. However the reliability of Hics depends not only on their own factors but also in their condition of usage.
When handling Hics, please note the following cautions.
CAUTIONS
Packing
Carrying
Storage
Extended storage
Maximum ratings
Polarity
The materials used in packing Hics can only withstand normal external conditions.
When exposed to outside shocks, rain and certain environmental contaminators, the packing materials
will deteriorates. Please take care in handling.
1) Don't stack boxes too high. Avoid placing heavy materials on boxes.
2) Boxes must be positioned correctly during transportation to avoid breakage.
3) Don't throw or drop boxes.
4) Keep boxes dry. Avoid rain or snow.
5) Minimal vibration and shock during transportation is desirable.
When storing Hics, please observe the following notices or possible deterioration of their electrical
characteristics, risk of solder ability, and external damage may occur.
1) Devices must be stored where fluctuation of temperature and humidity is minimal, and must not
be exposed to direct sunlight. Store at the normal temperature of 5 to 30 degrees Celsius with
humidity at 40 to 60%.
2) Avoid locations where corrosive gasses are generated or where much dust accumulates.
3) Storage cases must be static proof.
4) Avoid putting weight on boxes.
When extended storage is necessary, Hics must be kept non-processed. When using Hics which
have been stored for more than one year or under severe conditions, be sure to check that the exterior
is free from flaw and other damages.
To prevent any electrical damages, use Hics within the maximum ratings. The temperature, current,
voltage, etc. must not exceed these conditions.
To protect Hics from destruction and deterioration due to wrong insertion, make sure of polarity in
inserting leads into the board holes, conforming to the external view for the terminal arrangement.
IHYBRID IC
M57147AU-01
IPM POWER SUPPLY UNIT























Marketing division, Marketing planning department
6-41 Tsukuba, Isahaya, Nagasaki, 854-0065 Japan





Keep safety first in your circuit designs!
ISAHAYA Electronics Corporation puts the maximum effort into making semiconductor products better and more reliable, but
there is always the possibility that trouble may occur with them. Trouble with semiconductors may lead to personal injury, fire or
property damage. Remember to give due consideration to safety when making your circuit designs, with appropriate measures
such as (1) placement of substitutive, auxiliary, (2) use of non-farmable material or (3) prevention against any malfunction or
mishap.
Notes regarding these materials
These materials are intended as a reference to our customers in the selection of the ISAHAYA products best suited to the
customer's application; they don't convey any license under any intellectual property rights, or any other rights, belonging
ISAHAYA or third party.
ISAHAYA Electronics Corporation assumes no responsibility for any damage, or infringement of any third party's rights ,
originating in the use of any product data, diagrams, charts or circuit application examples contained in these materials.
All information contained in these materials, including product data, diagrams and charts, represent information on products
at the time of publication of these materials, and are subject to change by ISAHAYA Electronics Corporation without notice
due to product improvements or other reasons. It is therefore recommended that customers contact ISAHAYA Electronics
Corporation or an authorized ISAHAYA products distributor for the latest product information before purchasing product listed
herein.
ISAHAYA Electronics Corporation products are not designed or manufactured for use in a device or system that is used
under circumstances in which human life is potentially at stake. Please contact ISAHAYA electronics corporation or an
authorized ISAHAYA products distributor when considering the use of a product contained herein for any specific purposes,
such as apparatus or systems for transportation, vehicular, medical, aerospace, nuclear, or undersea repeater use.
The prior written approval of ISAHAYA Electronics Corporation is necessary to reprint or reproduce in whole or in part these
materials.
If these products or technologies are subject to the Japanese export control restrictions, they must be exported under a
license from the Japanese government and cannot be imported into a country other than the approved destination. Any
diversion or re-export contrary to the export control laws and regulations of Japan and/or the country of destination is
prohibited.
Please contact ISAHAYA Electronics Corporation or authorized ISAHAYA products distributor for further details on these
materials or the products contained therein.
Nov.2002