ChipFind - документация

Электронный компонент: 8ETX06S

Скачать:  PDF   ZIP
1
Bulletin PD-20766 rev. B 02/04
t
rr
= 15ns typ.
I
F(AV)
= 8Amp
V
R
= 600V
Hyperfast Recovery Time
Low Forward Voltage Drop
Low Leakage Current
175C Operating Junction Temperature
UL E78996 approved
Features
Description/ Applications
Absolute Maximum Ratings
Hyperfast Rectifier
V
RRM
Peak Repetitive Reverse Voltage
600
V
I
F(AV)
Average Rectified Forward Current @ T
C
= 143C
8
A
@ T
C
= 106C (FULLPACK)
I
FSM
Non Repetitive Peak Surge Current @ T
J
= 25C
110
I
FM
Peak Repetitive Forward Current
18
T
J
,
T
STG
Operating Junction and Storage Temperatures
- 65 to 175
C
Parameters
Max
Units
State of the art Hyperfast recovery rectifiers designed with optimized performance of forward voltage drop, Hyperfast
recover time, and soft recovery.
The planar structure and the platinum doped life time control guarantee the best overall performance, ruggedness
and reliability characteristics.
These devices are intended for use in PFC Boost stage in the AC-DC section of SMPS, inverters or as freewheeling
diodes.
The IR extremely optimized stored charge and low recovery current minimize the switching losses and reduce over
dissipation in the switching element and snubbers.
www.irf.com
8ETX06
8ETX06S
8ETX06-1
8ETX06FP
8ETX06
TO-220AC
Case Styles
8ETX06S
D
2
PAK
8ETX06-1
TO-262
Anode
1
3
Base
Cathode
2
N/C
Anode
1
3
Cathode
Base
Cathode
2
Anode
1
3
2
N/C
8ETX06FP
TO-220 FULLPACK
Anode
1
3
Cathode
2
8ETX06, 8ETX06S, 8ETX06-1, 8ETX06FP
Bulletin
PD-20766 rev. B 02/04
www.irf.com
V
BR
,
V
r
Breakdown Voltage,
600
-
-
V
I
R
= 100A
Blocking Voltage
V
F
Forward Voltage
-
2.3
3.0
V
I
F
= 8A, T
J
= 25C
-
1.4
1.7
V
I
F
= 8A, T
J
= 150C
I
R
Reverse Leakage Current
-
0.3
50
A
V
R
= V
R
Rated
-
35
500
A
T
J
= 150C, V
R
= V
R
Rated
C
T
Junction Capacitance
-
17
-
pF
V
R
= 600V
L
S
Series Inductance
-
8.0
-
nH
Measured lead to lead 5mm from package body
Electrical Characteristics @ T
J
= 25C (unless otherwise specified)
Parameters
Min Typ Max
Test Conditions
Units
t
rr
Reverse Recovery Time
-
15
19
ns
I
F
= 1A, di
F
/dt = 100A/s, V
R
= 30V
-
16
24
I
F
= 8A, di
F
/dt = 100A/s, V
R
= 30V
-
17
-
T
J
= 25C
-
40
-
T
J
= 125C
I
RRM
Peak Recovery Current
-
2.3
-
A
T
J
= 25C
-
4.5
-
T
J
= 125C
Q
rr
Reverse Recovery Charge
-
20
-
nC
T
J
= 25C
-
100
-
T
J
= 125C
t
rr
Reverse Recovery Time
-
31
-
ns
I
RRM
Peak Recovery Current
-
12
-
A
T
J
= 125C
Q
rr
Reverse Recovery Charge
-
195
-
nC
Dynamic Recovery Characteristics @ T
C
= 25C (unless otherwise specified)
I
F
= 8A
di
F
/dt = 200A/s
V
R
= 390V
Parameters
Min Typ Max
Test Conditions
Units
I
F
= 8A
di
F
/dt = 600A/s
V
R
= 390V
Parameters
Min
Typ
Max
Units
T
J
Max. Junction Temperature Range
-
-
175
C
T
Stg
Max. Storage Temperature Range
- 65
-
175
R
thJC
Thermal Resistance, Junction to Case
Per Leg
-
1.4
2
C/W
(Fullpack) Per Leg
-
3.4
4.3
R
thJA
Thermal Resistance, Junction to Ambient
Per Leg
-
-
70
R
thCS
Thermal Resistance, Case to Heatsink
-
0.5
-
Weight
-
2.0
-
g
-
0.07
-
(oz)
Mounting Torque
6.0
-
12
Kg-cm
5.0
-
10
lbf.in
Thermal - Mechanical Characteristics
Typical Socket Mount
Mounting Surface, Flat, Smooth and Greased
3
8ETX06, 8ETX06S, 8ETX06-1, 8ETX06FP
Bulletin
PD-20766 rev. B 02/04
www.irf.com
Fig. 1 - Typical Forward Voltage Drop Characteristics
Fig. 4 - Max. Thermal Impedance Z
thJC
Characteristics
Forward Voltage Drop - V
FM
(V)
Instantaneous Forward Current - I
F
(A)
Reverse Voltage - V
R
(V)
Reverse Voltage - V
R
(V)
Junction Capacitance - C
T
(
p
F
)
t
1
, Rectangular Pulse Duration (Seconds)
Thermal Impedance Z
thJC
(C/W)
Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage
Reverse Current - I
R
(A)
Fig. 2 - Typical Values Of Reverse Current
Vs. Reverse Voltage
0
0.001
0.01
0.1
1
10
100
1000
0
100 200 300 400 500 600
25C
T = 175C
J
100C
125C
150C
0.1
1
10
100
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
T = 175C
T = 150C
T = 25C
J
J
J
0.01
0.1
1
10
0.00001
0.0001
0.001
0.01
0.1
1
Single Pulse
(Thermal Resistance)
D = 0.50
D = 0.20
D = 0.10
D = 0.05
D = 0.02
D = 0.01
2
t
1
t
P
DM
Notes:
1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC + Tc
10
100
1000
0
100 200 300 400 500 600
T = 25C
J
4
8ETX06, 8ETX06S, 8ETX06-1, 8ETX06FP
Bulletin
PD-20766 rev. B 02/04
www.irf.com
Fig. 5 - Max. Thermal Impedance Z
thJC
Characteristics (FULLPACK)
t
1
, Rectangular Pulse Duration (Seconds)
Thermal Impedance Z
thJC
(C/W)
Fig. 6 - Max. Allowable Case Temperature
Vs. Average Forward Current
Average Forward Current - I
F
(AV)
(A)
Allowable Case Temperature (C)
Fig. 7 - Max. Allowable Case Temperature
Vs. Average Forward Current (FULLPACK)
Fig. 8 - Forward Power Loss Characteristics
Average Forward Current - I
F
(AV)
(A)
Average Forward Current - I
F
(AV)
(A)
Allowable Case Temperature (C)
Average Power Loss ( Watts )
(3) Formula used: T
C
= T
J
- (Pd + Pd
REV
) x R
thJC
;
Pd = Forward Power Loss =
I
F(AV)
x V
FM
@ (I
F(AV)
/
D)
(see Fig. 8);
Pd
REV
= Inverse Power Loss = V
R1
x I
R
(1 - D);
I
R
@ V
R1
= rated V
R
120
130
140
150
160
170
180
0
2
4
6
8
10
12
DC
see note (3)
Square wave (D = 0.50)
Rated Vr applied
0
2
4
6
8
10
12
14
16
18
20
0
2
4
6
8
10
12
14
DC
RMS Limit
D = 0.01
D = 0.02
D = 0.05
D = 0.1
D = 0.2
D = 0.5
0.01
0.1
1
10
0.00001
0.0001
0.001
0.01
0.1
1
10
100
Single Pulse
(Thermal Resistance)
D = 0.50
D = 0.20
D = 0.10
D = 0.05
D = 0.02
D = 0.01
2
t
1
t
P
DM
Notes:
1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC + Tc
40
60
80
100
120
140
160
180
0
2
4
6
8
10
12
DC
see note (3)
Square wave (D = 0.50)
Rated Vr applied
5
8ETX06, 8ETX06S, 8ETX06-1, 8ETX06FP
Bulletin
PD-20766 rev. B 02/04
www.irf.com
Fig. 10 - Typical Stored Charge vs. di
F
/dt
Fig. 9 - Typical Reverse Recovery vs. di
F
/dt
trr ( ns )
Qrr ( nC )
di
F
/dt (A/s )
di
F
/dt (A/s )
10
20
30
40
50
100
1000
R
J
J
V = 390V
T = 125C
T = 25C
IF = 16 A
IF = 8 A
IF = 16 A
IF = 8 A
0
50
100
150
200
250
300
100
1000
R
J
J
V = 390V
T = 125C
T = 25C
IF = 16 A
IF = 8 A
IF = 16 A
IF = 8 A
IRFP250
D.U.T.
L = 70H
V = 200V
R
0.01
G
D
S
dif/dt
ADJUST
Fig. 11- Reverse Recovery Parameter Test Circuit
Reverse Recovery Circuit
di
F
/dt
6
8ETX06, 8ETX06S, 8ETX06-1, 8ETX06FP
Bulletin
PD-20766 rev. B 02/04
www.irf.com
3.78 (0.15)
3.54 (0.14)
10.54 (0.41)
MAX.
DIA.
15.24 (0.60)
14.84 (0.58)
2.92 (0.11)
2.54 (0.10)
1
TERM 2
14.09 (0.55)
13.47 (0.53)
3.96 (0.16)
3.55 (0.14)
0.94 (0.04)
0.69 (0.03)
4.57 (0.18)
4.32 (0.17)
3
0.61 (0.02) MAX.
5.08 (0.20) REF.
1.32 (0.05)
1.22 (0.05)
6.48 (0.25)
6.23 (0.24)
2
0.10 (0.004)
1.40 (0.05)
1.15 (0.04)
2.89 (0.11)
2.64 (0.10)
1
3
2.04 (0.080) MAX.
Conforms to JEDEC Outline TO-220AC
Dimensions in millimeters and (inches)
Outline Table
Anode
1
3
Cathode
Base
Cathode
2
t
a
t
b
t
rr
Q
rr
I
F
I
RRM
I
RRM
0.5
di(rec)M/dt
0.75 I
RRM
5
4
3
2
0
1
di /dt
f
Fig. 12 - Reverse Recovery Waveform and Definitions
di
F
/dt
4. Q
rr
- Area under curve defined by t
rr
and I
RRM
5. di (rec) M / dt - Peak rate of change of
current during t b portion of t rr
1. di
F
/dt - Rate of change of current through zero
crossing
2. I
RRM
- Peak reverse recovery current
3. t
rr
- Reverse recovery time measured from zero
crossing point of negative going I
F
to point where
a line passing through 0.75 I
RRM
and 0.50 I
RRM
extrapolated to zero current
Q rr =
t rr x I RRM
2
7
8ETX06, 8ETX06S, 8ETX06-1, 8ETX06FP
Bulletin
PD-20766 rev. B 02/04
www.irf.com
10.16 (0.40)
REF.
8.89 (0.35)
4.57 (0.18)
4.32 (0.17)
0.61 (0.02) MAX.
5.08 (0.20) REF.
1.32 (0.05)
1.22 (0.05)
1
3
6.47 (0.25)
6.18 (0.24)
93
REF.
2.61 (0.10)
2.32 (0.09)
5.28 (0.21)
4.78 (0.19)
4.69 (0.18)
4.20 (0.16)
0.55 (0.02)
0.46 (0.02)
14.73 (0.58)
15.49 (0.61)
1.40 (0.055)
1.14 (0.045)
3X
0.93 (0.37)
0.69 (0.27)
2X
11.43 (0.45)
17.78 (0.70)
8.89 (0.35)
3.81 (0.15)
2.08 (0.08)
2X
2.54 (0.10)
2X
MINIMUM RECOMMENDED FOOTPRINT
2
Modified JEDEC outline TO-262
Dimensions in millimeters and (inches)
NC
Anode
1
3
2
N/C
Outline Table
Conforms to JEDEC Outline D
2
PAK
Dimensions in millimeters and (inches)
Anode
1
3
Base
Cathode
2
N/C
8
8ETX06, 8ETX06S, 8ETX06-1, 8ETX06FP
Bulletin
PD-20766 rev. B 02/04
www.irf.com
5 0.5
3
.
1
3
.
3
1
3
.
5
1
3
.
7
R0.5
R0.7 (2 PLACES)
3.1
HOLE 3.4
10.4
0.7
4
.
6
TYP.
5 0.5
4
.
8
0.9
2.54 TYP.
2.54
10.6
1
6
.
4
1
6
.
0
3
.
7
7
.
1
0.48
2.85
2.8
1.4
1.15
1
5
.
4
3
.
2
6
.
7
1
5
.
8
1.05
1.3
0.44
2.65
2.6
TYP
10
Outline Table
Ordering Information Table
Device Code
1
5
2
4
3
1
-
Current Rating (8 = 8A)
2
-
E
= Single Diode
3
-
T
= TO-220, D
2
Pak
4
-
X
= HyperFast Recovery
5
-
Voltage Rating (06 = 600V)
6
-
"-1" = TO-262 Option
S
= D
2
Pak
None = TO-220AC
FP
= TO-220 FULLPACK
8
E
T
X
06
- 1
6
Conforms to JEDEC Outline TO-220 FULLPACK
Dimensions in millimeters and (inches)
Anode
1
3
Cathode
9
8ETX06, 8ETX06S, 8ETX06-1, 8ETX06FP
Bulletin
PD-20766 rev. B 02/04
www.irf.com
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 02/04
Data and specifications subject to change without notice.
This product has been designed and qualified for Industrial Level.
Qualification Standards can be found on IR's Web site.