MODEL
UAF500S-3
UAF500S-5
UAF500S-12
UAF500S-24
UAF500S-48
MAX OUTPUT WATTAGE[W]
300
500
516
528
528
DC OUTPUT
3V 100A
5V 100A
12V 43A
24V 22A
48V 11A
SPECIFICATIONS
MODEL
UAF500S-3
UAF500S-5
UAF500S-12
UAF500S-24
UAF500S-48
INPUT
VOLTAGE[V]
AC85 - 264 1
f
(Rated input:AC100 / 200)
CURRENT[A]
ACIN 100V 4.5typ (Io=100%)
6.8typ (Io=100%)
ACIN 200V 2.3typ (Io=100%)
3.4typ (Io=100%)
FREQUENCY[Hz]
50/60 (47 - 63)
EFFICIENCY[%]
67typ
74typ
77typ
77typ
80typ
POWER FACTOR
0.99typ (At rated input/output)
INRUSH CURRENT[A]
ACIN 100V 15typ (Io=100%)
ACIN 200V 30typ (Io=100%)
LEAKAGE CURRENT[mA]
0.75max
OUTPUT
VOLTAGE[V]
3
5
12
24
48
CURRENT[A]
100
100
43
22
11
LINE REGULATION[mV]
40max
40max
80max
100max
192max
LOAD REGULATION[mV]
80max
80max
120max
160max
300max
RIPPLE[mVp-p]
0 to +50
C
*
1
100max
100max
120max
120max
150max
-10 - 0
C
*
1
120max
120max
150max
150max
200max
RIPPLE NOISE[mVp-p]
0 to +50
C
*
1
120max
120max
150max
150max
350max
-10 - 0
C
*
1
180max
180max
200max
200max
400max
TEMPERATURE REGULATION[mV] 40max
50max
160max
200max
480max
DRIFT[mV]
*
2
12max
20max
48max
96max
192max
START-UP TIME[ms]
800max (ACIN 85V, Io=100%)
HOLD-UP TIME[ms]
30typ
20typ
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6
+10%, -5%
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
4.00 - 5.25V
Works at 115 - 140% of rating
OPERATING INDICATION
LED (Green)
REMOTE SENSING
Provided
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 25mA, DC500V 50M
W
min (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 25mA, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +60
C
, 10 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 10 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1, CSA C22.2 No.234, EN60950-1, EN50178 Complies with IEC60950-1
CONDUCTED NOISE
Complies with FCC-B, CISPR22-B, EN55022-B, VCCI-B
HARMONIC ATTENUATOR
Complies with IEC61000-3-2
OTHERS
CASE SIZE/WEIGHT
140
X
45
X
278 (308) mm (without terminal block) (W
X
H
X
D) /2.4kg max, 2.6kg max (with fan unit)
COOLING METHOD
Forced air
*
1
Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN:RM101).
*
2
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25
C
, with the input voltage held constant at the rated input/output.
UAF500S
Unit type
UA
F
500
S
-5
-
O
Ordering information
1
Series name
2
Universal input
3
Output wattage
4
Single output
5
Output voltage
6
Optional
C :with Coating
F :with Fan unit
G :Low leakage current
R :with Remote ON/OFF
R
1
2
3
4
5
6
UAF
A-162
The forced air with the fan is necessary.
RoHS : Please consult us for details
HARMOINC CURRENT (UAF500S-5)
OVERCURRENT CHARACTERISTICS (UAF500S-5)
RISE TIME & FALL TIME (UAF500S-5)
HARMONIC CURRENT (UAF500S-5)
UAF
A-163
UAF500S
External view
Dimensions with ( )is for
reference.
Weight : 2.4kg or less
(2.6kg or less when
Fan unit is attached)
Tolerance :
t1
Dimensions in mm.
Cover : Aluminum
Maximum 50A per pin of
TB2 .
Mounting torque:
1.2N . m(12.8kgf . cm)max
I/O Connector
CN1 S10B-ZR
ZHR-10
Chain: SZH-002T-P0.5
Loose: BZH-002T-P0.5
(Mfr.J.S.T.)
Mating Connector
Terminal
"A" means connection
is not possible.
Performance data