ChipFind - документация

Электронный компонент: LDA50F-18

Скачать:  PDF   ZIP

Document Outline

MODEL
P15E-5
P15E-9
P15E-12
P15E-15
P15E-18
P15E-24
P15E-30
P15E-48
MAX OUTPUT WATTAGE[W]
15
15.3
15.6
15
16.2
16.8
15
16.8
DC OUTPUT
5V 3A
9V 1.7A
12V 1.3A
15V 1A
18V 0.9A
24V 0.7A
30V 0.5A
48V 0.35A
SPECIFICATIONS
MODEL
P15E-5
P15E-9
P15E-12
P15E-15
P15E-18
P15E-24
P15E-30
P15E-48
INPUT
VOLTAGE[V]
AC85 - 264 1
f
or DC110 - 370
CURRENT[A]
ACIN 100V
*
1
0.3typ (Io=100%)
ACIN 200V
*
1
0.18typ (Io=100%)
FREQUENCY[Hz]
47 - 440 or DC
EFFICIENCY[%]
73typ
75typ
79typ
81typ
81typ
81typ
81typ
81typ
INRUSH CURRENT[A]
ACIN 100V 20typ (Io=100%) (At cold start)
ACIN 200V 40typ (Io=100%) (At cold start)
OUTPUT
VOLTAGE[V]
5
9
12
15
18
24
30
48
CURRENT[A]
3.0
1.7
1.3
1.0
0.9
0.7
0.5
0.35
MAX OUTPUT WATTAGE[W] 15.0
15.3
15.6
15.0
16.2
16.8
15.0
16.8
LINE REGULATION[mV]
20max
36max
48max
60max
72max
96max
120max
192max
LOAD REGULATION[mV] 40max
70max
100max
120max
140max
150max
180max
380max
RIPPLE[mVp-p]
*
2
80max
120max
120max
120max
120max
120max
120max
150max
RIPPLE NOISE[mVp-p]
*
2
120max
150max
150max
150max
150max
150max
150max
250max
TEMPERATURE REGULATION[mV] 0 to +50
C
50max
90max
120max
150max
180max
240max
300max
480max
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
t
10%
START-UP TIME[ms]
100max (ACIN 85V, Io=100%)
HOLD-UP TIME[ms]
10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%)
PROTECTION
CIRCUIT
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115 - 140% of rating
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +65
C
, 30 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 30minutes each along X, Y and Z axis
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1
CONDUCTED NOISE
Complies with FCC-B
*
1
The input current of the agency approved unit is indicated as 0.4A.
*
2
According to 15MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*
Derating is required when operated with case cover.
*
Parallel operation with other model is not possible.
P15E
Unit type
P
15
E
-5
-
O
Ordering information
1
Series name
2
Output wattage
3
UL recognized,T
u
V
approved,
CSA certified:E
4
Output voltage
5
Optional
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
R
1
2
3
4
5
P
A-70
DERATING CURVE
OVERCURRENT CHARACTERISTICS
(P15E-5)
RISE TIME & FALL TIME
(P15E-5)
STATIC CHARACTERISTICS
(P15E-5)
P
A-71
P15E
External view
CN2
FG
NC
AC(N)
AC(L)
CN1
+
-
21
13.5
17
11
18
9.5
7.5
FG
AC(N)
AC(L)
+
-
Voltage Adjust
Name Plate
for Cover
LED
Name Plate
Safety
Cover
Name Plate
Protection
Safety Ground4
Optional Cover
max
M3
55 +
-0.5
74+
-0.5
97
39
35
25
71
89
82
23.5
99.5
117
55.5
45.5
77.5
3.5
17.5
3.5
5.5
3.5
3.5
3.5
2-3.5
Mounting
Hole
2-M3
Mounting
Hole
2-M3
6
5
7
Weight : 300g or less (without
Cover is optional
Tolerance :
t1
Dimensions in mm.
Connector type
Barrier strip type
cover)
Mounting torque:0.6N . m(6.3kgf . cm)max
I/O Connector
CN1 5289-4A
5199-04
Chain: 5194PBT
Loose: 5194PBTL
CN2 5277-4A
5196-04
Chain: 5194PBT
Loose: 5194PBTL
(Mfr : Molex)
Mating Connector
Terminal
99.5
Performance data
MODEL
P30E-5
P30E-9
P30E-12
P30E-15
P30E-18
P30E-24
P30E-30
P30E-48
MAX OUTPUT WATTAGE[W]
30
30.6
30
30
30.6
31.2
30
30.24
DC OUTPUT
5V 6A
9V 3.4A
12V 2.5A
15V 2A
18V 1.7A
24V 1.3A
30V 1.0A
48V 0.63A
SPECIFICATIONS
MODEL
P30E-5
P30E-9
P30E-12
P30E-15
P30E-18
P30E-24
P30E-30
P30E-48
INPUT
VOLTAGE[V]
AC85 - 264 1
f
or DC110 - 370
CURRENT[A]
ACIN 100V
*
1
0.6typ (Io=100%)
ACIN 200V
*
1
0.35typ (Io=100%)
FREQUENCY[Hz]
47 - 440 or DC
EFFICIENCY[%]
74typ
74typ
78typ
79typ
79typ
82typ
82typ
82typ
INRUSH CURRENT[A]
ACIN 100V 20typ (Io=100%) (At cold start)
ACIN 200V 40typ (Io=100%) (At cold start)
OUTPUT
VOLTAGE[V]
5
9
12
15
18
24
30
48
CURRENT[A]
6.0
3.4
2.5
2.0
1.7
1.3
1.0
0.63
MAX OUTPUT WATTAGE[W] 30
30.6
30
30
30.6
31.2
30
30.24
LINE REGULATION[mV]
20max
36max
48max
60max
72max
96max
120max
192max
LOAD REGULATION[mV] 40max
70max
100max
120max
140max
150max
180max
300max
RIPPLE[mVp-p]
*
2
80max
120max
120max
120max
120max
120max
120max
150max
RIPPLE NOISE[mVp-p]
*
2
120max
150max
150max
150max
150max
150max
150max
250max
TEMPERATURE REGULATION[mV] 0 to +50
C
50max
90max
120max
150max
180max
240max
300max
480max
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
t
10%
START-UP TIME[ms]
100max (ACIN 85V, Io=100%)
HOLD-UP TIME[ms]
10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%)
PROTECTION
CIRCUIT
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115 - 140% of rating
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +65
C
, 30 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 30minutes each along X, Y and Z axis
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1
CONDUCTED NOISE
Complies with FCC-B
*
1
The input current of the agency approved unit is indicated as 0.7A.
*
2
According to 15MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*
Derating is required when operated with case cover.
*
Parallel operation with other model is not possible.
P30E
Unit type
P
30
E
-5
-
O
Ordering information
1
Series name
2
Output wattage
3
UL recognized,T
u
V
approved,
CSA certified:E
4
Output voltage
5
Optional
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
R
1
2
3
4
5
P
A-72
DERATING CURVE
OVERCURRENT CHARACTERISTICS (
P30E-5
)
RISE TIME & FALL TIME (
P30E-5
)
STATIC CHARACTERISTICS (
P30E-5
)
P
A-73
P30E
External view
CN2
FG
NC
AC(N)
AC(L)
CN1
+
-
21
13.5
17
11
18
7.5
FG
AC(N)
AC(L)
+
-
Voltage Adjust
Name Plate
for Cover
LED
Safety
Cover
Name Plate
Optional Cover
max
M3
55+
-0.5
83+
-0.5
97
39
35
25
71
114
105
34
124.5
142
55.5
42.5
77.5
3.5
17.5
5.5
3.5
3.5
3.5
Mounting Hole
2-M3
Mounting
Hole
2-M3
6
5
7
Weight : 400g or less(without
Cover is optional
Tolerance :
t1
Dimensions in mm.
Name Plate
Protection
Safety Ground4
2-3.5
Connector type
Barrier strip type
9.5
15
3.5
cover)
Mounting torque:0.6N . m(6.3kgf . cm)max
I/O Connector
CN1 5289-4A
5199-04
Chain: 5194PBT
Loose: 5194PBTL
CN2 5277-4A
5196-04
Chain: 5194PBT
Loose: 5194PBTL
(Mfr : Molex)
Mating Connector
Terminal
124.5
Performance data
MODEL
P50E-5
P50E-9
P50E-12
P50E-15
P50E-18
P50E-24
P50E-30
P50E-48
MAX OUTPUT WATTAGE[W]
50
49.5
50.4
51
50.4
50.4
51
48
DC OUTPUT
5V 10A
9V 5.5A
12V 4.2A
15V 3.4A
18V 2.8A
24V 2.1A
30V 1.7A
48V 1.0A
SPECIFICATIONS
MODEL
P50E-5
P50E-9
P50E-12
P50E-15
P50E-18
P50E-24
P50E-30
P50E-48
INPUT
VOLTAGE[V]
AC85 - 132 / 170 - 264 1
f
(User-selectable) or DC220 - 370
CURRENT[A]
ACIN 100V
*
1
1.2typ (Io=100%)
ACIN 200V
*
1
0.61typ (Io=100%)
FREQUENCY[Hz]
47 - 440
EFFICIENCY[%]
72typ
77typ
77typ
78typ
78typ
80typ
82typ
80typ
INRUSH CURRENT[A]
ACIN 100V 20typ (Io=100%) (At cold start)
ACIN 200V 40typ (Io=100%) (At cold start)
OUTPUT
VOLTAGE[V]
5
9
12
15
18
24
30
48
CURRENT[A]
10
5.5
4.2
3.4
2.8
2.1
1.7
1.0
MAX OUTPUT WATTAGE[W] 50
49.5
50.4
51
50.4
50.4
51
48
LINE REGULATION[mV]
20max
36max
48max
60max
72max
96max
120max
192max
LOAD REGULATION[mV] 40max
70max
100max
120max
144max
150max
180max
240max
RIPPLE[mVp-p]
*
2
80max
120max
120max
120max
120max
120max
120max
150max
RIPPLE NOISE[mVp-p]
*
2
120max
150max
150max
150max
150max
150max
150max
250max
TEMPERATURE REGULATION[mV] 0 to +50
C
50max
120max
120max
150max
180max
240max
350max
480max
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
t
10%
START-UP TIME[ms]
100max (ACIN 85V, Io=100%)
HOLD-UP TIME[ms]
10typ (ACIN 85V, Io=100%) 20typ (ACIN 100V, Io=100%)
PROTECTION
CIRCUIT
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION
Works at 115 - 140% of rating
ISOLATION
INPUT-OUTPUT
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50M
W
min (At Room Temperature)
OUTPUT-FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50M
W
min (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +65
C
, 30 - 90%RH (Non condensing) (Refer to DERATING CURVE), 3,000m (10,000feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75
C
, 20 - 90%RH (Non condensing), 9,000m (30,000feet) max
VIBRATION
10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 30minutes each along X, Y and Z axis
IMPACT
196.1m/s
2
(20G), 11ms, once each X, Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1, EN60950-1, EN50178, CSA C22.2 No.234 Complies with DEN-AN and IEC60950-1
CONDUCTED NOISE
Complies with FCC-B
*
1
The input current of the agency approved unit is indicated as 1.1A (ACIN 100V) or 0.6A (ACIN 200V).
*
2
According to 15MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*
Derating is required when operated with case cover.
*
Parallel operation with other model is not possible.
P50E
Unit type
P
50
E
-5
-
O
Ordering information
1
Series name
2
Output wattage
3
UL recognized,T
u
V
approved,
CSA certified:E
4
Output voltage
5
Optional
C :with Coating
G :Low leakage current
J :Connector type
N :with Cover
R
1
2
3
4
5
P
A-74