Special Features
60 Watts
DAS60
Electrical Specs
CE Mark EMC & LVD
Universal AC input
Fully regulated output
Overload and short circuit protection
Thermal protection
Blue Angel compliance
Constant voltage
High efficiency
High MTBF
IEC320 AC receptacle, 3 pin (type C14)
Built in EMI filter (CISPR 22 Class B)
LED power good indicator
Input
Input range
90 - 264 VAC (wide range)
Frequency
47 - 63 Hz
Inrush current
50A @ 230 VAC, cold start @ 25C
Input current
1.5A rms @ 90 VAC; 0.5A @ 264VAC
Efficiency
>80% @ full load typical, @115VAC
EMI/RFI
FCC Part 15, Subpart B Class B & EN55022
(CISPR 22) Class B
Safety ground
leakage current
300A max. @ 50/60 Hz, 230 VAC input
Output
Voltage (Vo)
48V
Voltage regulation
2% @ constant voltage mode
Maximum Power (Po)
60W
Hold-up time
20 ms. typical at full load @ 115VAC
Overvoltage protection
25% above nominal output maximum.
Latching type, recycle AC to reset.
Overload protection
Output short circuit protection auto recover.
Overload protected @ 150% above maximum
rating.
Overtemperature
protection
Auto recovery
Cable/connector
DC cable with 2.5 mm center plug
barrel type
DC plug center +v
DC plug outer -v
Operating temperature: -5C to +50C ambient
Storage temperature: -40C to +70C
Electromagnetic susceptability; design to meet
EN61000-4,-2,-4,-5,-6,-11, level 3
Humidity: Operating; non-condensing; 10% to
90% RH
Vibration: Three orthogonal axes, sweep at 1
oct/min. 5 min. dwell at four major resonances 2G
peak 8 Hz to 500 Hz, operational
MTBF demonstrated: >550,000 hours at full load
and 25C ambient conditions
UL
60950
CUL
60950
NEMKO
60950
TUV
60950
CB
Certificate and report
CE
EMC & LVD
Environmental
Safety
Total Power:
60 Watts
Input Voltage:
90-264 VAC
# of Outputs:
Single
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
191
www.astecpower.com
Ordering Information
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Model
Power Vo
Regulation
Io max
Ripple
Max
DAS60-480
60W
48V
2%
1.25 A
480 mV
1. Peak-to-peak with 20 MHz bandwidth and 10 F in parallel with a 0.1 F capacitor.
72.00 (1830)
2.00 (50.8)
3.28 (83.8)
6.18 (157.5)
DAS60
NOTES:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is
.02"
3. Warranty: 1 year
4. Weight: 1.06 lb./ .48 kg
5. AC input power cord sold separately.