Special Features
Electrical Specs
INPUT
DC input
-40 VDC to 75 VDC
Transients
ANSI T1.315-1994, FTZ19, BTR2511
Input feeds
4 x 100A each
4 x 150A each (available in the future)
OUTPUT
DC output
20 x 25A breakers total
Four breaker modules,
each with 5 x 25A breakers
Alarm signals
Critical, major, minor alarms
48V 400-600 Amp
Breaker Panel (BIP)
AP6C64AA
Low profile:
Fits in 2U height,
3.47", 88.1 mm
23" width
4 x 100 A input feeds, upgradeable to 4 x 150A
input feeds
supports A & B redundant input feeds
4 hot swappable Breaker Modules + one Alarm
Module
Breaker Modules available in various configurations,
all come equipped with:
28,200 F capacitor bank
automatic inrush current limiting
hot swappable, field replaceable without
service interruption
Breaker Module configurations:
5A 5A 5A 5A 5A
20A 20A 20A 20A 20A
25A 25A 5A 25A 25A
10A 5A 30A 5A 10A
25A 25A 25A 25A 25A
30A 30A 5A 30A 30A
other configurations available on request,
please consult your Astec representative
Standard Alarm module comes equipped with:
isolated alarm contacts
input feed fail alarm
output breaker trip alarm
critical, major, minor alarms
end aisle lamp drive
fully programmable, 6 bit, shelf ID
LED test switch
connections for voice and data jacks
Enhanced, customized alarm modules available by
special order
EMC/EMI:
No switching components, inherently
EMI/EMC benign
ESD:
Bellcore GR-1089-CORE, ETSI 300 386-1,
(15kV)
Operating Temperature and Humidity
-5C to +55C normal, 5% to 85% RH, non-condensing
-8C to +65C short term
Shock and
Vibration:
Bellcore GR-063-CORE and ETSI 300 019
Zone 4 earthquake
Fire Resistance:
UL94V-0
U
ULL
1950
C
CS
SA
A
C22.2 950
E
EN
N
60850, 41003
B
Be
ellllcco
orre
e
GR-063-CORE
Environmental
Safety
A breaker interface panel, also knows as a power distribution unit
(PDU), or frame supervisory panel (FSP), improves system power
stability and provides a convenient centralized location for all
customer load circuit breakers, alarms, and filtering.
A
AS
SIIA
A
U
Un
niittss 2
21
11
11
1--2
21
11
16
6,, LLe
evve
ell 2
21
1
T
To
ow
we
err1
1,, M
Me
ettrro
op
pllaazzaa
2
22
23
3,, H
Hiin
ng
g FFo
on
ng
g R
Ro
oaad
d
F
Fw
waaii FFo
on
ng
g,, N
Ne
ew
w T
Te
errrriitto
orriie
ess
H
Ho
on
ng
g K
Ko
on
ng
g
T
Te
elle
ep
ph
ho
on
ne
e:: 8
85
52
2--2
24
43
37
7--9
96
66
62
2
F
Faaccssiim
miille
e:: 8
85
52
2--2
24
40
02
2--4
44
42
26
6
E
EU
UR
RO
OP
PEE
A
Asstte
ecc H
Ho
ou
usse
e,, W
Waatte
errffrro
on
ntt B
Bu
ussiin
ne
essss P
Paarrkk
M
Me
errrryy H
Hiillll,, D
Du
ud
dlle
eyy
W
We
esstt M
Miid
dllaan
nd
dss,, D
DY
Y5
5 1
1LLX
X,, U
UK
K
T
Te
elle
ep
ph
ho
on
ne
e:: 4
44
4 ((1
13
38
84
4)) 8
84
42
2--2
21
11
1
F
Faaccssiim
miille
e:: 4
44
4 ((1
13
38
84
4)) 8
84
43
3--3
35
55
5
A
AM
MEER
RIIC
CA
AS
S
5
58
81
10
0 V
Vaan
n A
Alllle
en
n W
Waayy
C
Caarrllssb
baad
d,, C
CA
A 9
92
20
00
08
8
T
Te
elle
ep
ph
ho
on
ne
e:: 7
76
60
0--9
93
30
0--4
46
60
00
0
F
Faaccssiim
miille
e:: 7
76
60
0--9
93
30
0--0
06
69
98
8